Partner Login
Home | Careers | Contact Us | Our Locations | International | Search
Xtralis
The sooner you know™

 

ICAM ECO by Xtralis ASD Plus Gas Detection and Environmental Monitoring

Xtralis has extended its ICAM range of aspirating smoke detection (ASD) systems to include reliable gas detection and environmental monitoring. Invisible hazards can originate from the release of toxic gases, oxygen deficiency, or the presence of combustible gases/vapors. As with fire detection, proactive gas detection enables countermeasures to be taken to protect personnel and property from such unseen dangers.

ICAM ECO by XtralisICAM ECO by Xtralis uses an existing ICAM pipe network to actively sample air for the presence of smoke as well as hazardous/combustible gases. Integration with other building systems (FACP, PLC, HVAC and BMS) delivers real-time situational awareness and intelligent emergency response, including the activation of demand-controlled ventilation to save energy and control costs.

 

 

 

 

ICAM ECO Benefits

  • Leverages existing ICAM pipe networks to cost effectively detect both smoke and gas in addition to providing environmental monitoring
  • Provides detection for multiple gases through simple expansion without major construction or retrofitting
  • Reduces energy consumption and costs through demand-controlled ventilation
  • Conditions air to remove dirt, particulates, moisture, poisonous agents, and cross-interference gases
  • Works in harsh environments
  • Provides non-intrusive detection for aesthetics or to prevent vandalism
  • Enables centralized monitoring and communication with building systems for real-time awareness
  • Integrates easily with FACP/PLC/HVAC/BMS

Gas Detection and Ranges
Each ICAM ECO detector can house up to two gas sensors, and additional detectors can be added easily to the pipe network to monitor more gases if required. In its initial release, ICAM ECO can be configured to detect:

  • Ammonia (NH3) 0-100 ppm
  • Carbon Monoxide (CO) 0-500 ppm
  • Hydrogen (H2) 0-100% LEL
  • Hydrogen Sulphide (H2S) 0-100 ppm
  • Methane (CH4) 0-100% LEL
  • Nitrogen Dioxide (NO2) 0-10 ppm
  • Oxygen (O2) 0-25% V
  • Propane (C3H8) 0-100% LEL
  • Sulphur Dioxide (SO2) 0-10 ppm

Applications
ICAM ECO provides point, zone or total-area coverage to suit different applications in a wide array of environments including:

 

 



  


Copyright 2010 Xtralis Pty Ltd. All Rights Reserved. | Terms of Use | Privacy Policy | Licenses | Site Map   
Copyright 2010 Xtralis Pty Ltd. All Rights Reserved.