VESDA-E VEP Aspirating Smoke Detector (Mainstream ASD)

The VESDA-E VEP series of smoke detectors bring the latest and most advanced detection technology to provide very early warning and the best nuisance alarm rejection to a wide range of applications. Built on the Flair detection technology and years of application experience, VEP detectors achieve consistent performance over their lifetime via absolute calibration. In addition, the VEP delivers a range of revolutionary features that provide user value.

Model Nos. VEP-A00-1P, VEP-A00-P, VEP-A10-P, VEP-A00-1P-UL, VEP-A00-P-UL, VEP-A10-P-UL
Play Video VESDA-E VEP Introduction
 

FEATURES
APPLICATIONS
CERTIFICATIONS
ACCESSORIES
SERVICE & SUPPORT
  • Suitable for Class 1 Division 2 applications - Groups A,B,C & D
  • One and four pipe models for different applications
  • Flair detection technology delivers reliable very early warning in a wide range of environments with minimal nuisance alarms
  • Short wavelength laser-based detection:
    • High sensitivity from small particle light scattering
    • No drift compensation required since focused light directed at target gives low backgrounds
    • High stability with temperature and time
  • Multi stage filtration and optical protection with clean air barriers ensures lifetime detection performance
  • Four alarm levels and a wide sensitivity range deliver optimum protection for the widest range of applications
  • Intuitive LCD icon display provides instant status information for immediate response
  • Flow fault thresholds per port accommodate varying airflow conditions
  • Smart on-board filter retains dust count and remaining filter life for predictable maintenance
  • Extensive event log (20,000 events) for event analysis and system diagnostics
  • AutoLearn™ smoke and flow for reliable and rapid commissioning
  • Referencing to accommodate external environmental conditions to minimise nuisance alarms
  • Backward compatible with VLP and VESDAnet
  • Ethernet for connectivity with Xtralis software for configuration, secondary monitoring and maintenance
  • USB for PC configuration, and firmware upgrade using a memory stick
  • Two programmable GPIs (1 monitored) for flexible remote control
  • Field replaceable sub-assemblies enable faster service and maximum uptime

FEATURES
  • Suitable for Class 1 Division 2 applications - Groups A,B,C & D
  • One and four pipe models for different applications
  • Flair detection technology delivers reliable very early warning in a wide range of environments with minimal nuisance alarms
  • Short wavelength laser-based detection:
    • High sensitivity from small particle light scattering
    • No drift compensation required since focused light directed at target gives low backgrounds
    • High stability with temperature and time
  • Multi stage filtration and optical protection with clean air barriers ensures lifetime detection performance
  • Four alarm levels and a wide sensitivity range deliver optimum protection for the widest range of applications
  • Intuitive LCD icon display provides instant status information for immediate response
  • Flow fault thresholds per port accommodate varying airflow conditions
  • Smart on-board filter retains dust count and remaining filter life for predictable maintenance
  • Extensive event log (20,000 events) for event analysis and system diagnostics
  • AutoLearn™ smoke and flow for reliable and rapid commissioning
  • Referencing to accommodate external environmental conditions to minimise nuisance alarms
  • Backward compatible with VLP and VESDAnet
  • Ethernet for connectivity with Xtralis software for configuration, secondary monitoring and maintenance
  • USB for PC configuration, and firmware upgrade using a memory stick
  • Two programmable GPIs (1 monitored) for flexible remote control
  • Field replaceable sub-assemblies enable faster service and maximum uptime
APPLICATIONS
  • Accommodation (Apartments, Hotels, Shops and Offices)
  • Correctional Facilities
  • Clean Rooms
  • Cold Storage
  • Cultural/Heritage
  • Data & Telecom
  • Education
  • Hospitals & Healthcare
  • Insurance
  • Marine
  • Nuclear Facilities
  • Offices
  • Oil & Gas
  • Portable Switch Rooms
  • Power Generation
  • Records Storage
  • Retail
  • Transportation
  • Wind Power Generation
  • Warehousing
  • And more...
CERTIFICATIONS

INTERNATIONAL EDITION

  • VdS (EN54-20)
  • CE
  • UKCA
  • CSFM
  • FM
  • FDA
  • AFNOR
  • ActivFire (ISO 7240-20)
  • BOMBA
  • RCM
  • CCCF

UL268 7TH EDITION 

  • UL 268 7th Edition
  • ULC
  • CSFM
  • FM
  • FDA
  • FCC
  • RCM
  • KFI

Classification of any configuration is determined using ASPIRE. Regional approvals listings and regulatory compliance vary between product models. Refer to www.xtralis.com for the latest product approvals matrix.

DoP available for download here.

ACCESSORIES
VESDA-E Remote Accessories
VESDA-E Remote Accessories
Xtralis Test Transformer
Xtralis Test Transformer
F-PC
ASD Sampling Hole Clips
VESDA Pipe - Fittings
VESDA E & VESDA Pipe & Fittings
Refrigerated Storage Sampling Kit
Refrigerated Storage Sampling Kit
Tamper Proof Sampling Point
Tamper Proof Sampling Point
Flush Mount Sampling Point
Flush Mount Sampling Point
VESDA-E Power Supply
VESDA-E Power Supply
VESDA-E - VESDA Filters
VESDA-E & VESDA Filters
Xtralis In-Line Filter
Xtralis In-Line Filter
Automatic Purging Unit
Automatic Purging Unit
VESDA HLI
VESDA High Level Interface (HLI)
VESDA Remote Display Module
VESDA Remote Display Module
VESDA 19 Subrack
VESDA 19" Sub Rack
VESDA LCD Programmer
VESDA LCD Programmer
Smoke Pen
Smoke Pen
SERVICE & SUPPORT

Please visit the Document Library for access to software, manuals, engineering specifications, application notes and other technical support documents.

RESOURCES (International Edition)



RESOURCES (UL268 7th Edition (AMERICAs ONLY))




VIDEOS

VESDA-E VEP Introduction
Play Video: VESDA-E VEP Introduction
VESDA-E VEP Introduction
VESDA-E VEP: How to Prepare the VEP Detector
Play Video: VESDA-E VEP: How to Prepare the VEP Detector
VESDA-E VEP: How to Prepare the VEP Detector
VESDA-E VEP/VEU/VES - How to Prepare the Detector for Mounting
Play Video: VESDA-E VEP/VEU/VES - How to Prepare the Detector for Mounting
VESDA-E VEP/VEU/VES - How to Prepare the Detector for Mounting
VESDA-E VEP/VEU/VES: How to Mount the Detector Using the Template
Play Video: VESDA-E VEP/VEU/VES: How to Mount the Detector Using the Template
VESDA-E VEP/VEU/VES: How to Mount the Detector Using the Template
VESDA-E VEP/VEU/VES: How to Mount the Detector Using the Bracket
Play Video: VESDA-E VEP/VEU/VES: How to Mount the Detector Using the Bracket
VESDA-E VEP/VEU/VES: How to Mount the Detector Using the Bracket
VESDA-E VEP/VEU/VES: How to Initiate AutoConfig Function as Part of Commissioning
Play Video: VESDA-E VEP/VEU/VES: How to Initiate AutoConfig Function as Part of Commissioning
VESDA-E VEP/VEU/VES: How to Initiate AutoConfig Function as Part of Commissioning
VESDA-E VEP/VEU/VES: How to Interface to the Detector
Play Video: VESDA-E VEP/VEU/VES: How to Interface to the Detector
VESDA-E VEP/VEU/VES: How to Interface to the Detector
VESDA-E VEP/VEU/VES: How to Invert the Detector
Play Video: VESDA-E VEP/VEU/VES: How to Invert the Detector
VESDA-E VEP/VEU/VES: How to Invert the Detector
VESDA-E VEP/VEU/VES: How to Read the 3.5 inch LCD Display
Play Video: VESDA-E VEP/VEU/VES: How to Read the 3.5 inch LCD Display
VESDA-E VEP/VEU/VES: How to Read the 3.5 inch LCD Display
VESDA-E VEP/VEU/VES: How to Replace the Aspirator in a Detector
Play Video: VESDA-E VEP/VEU/VES: How to Replace the Aspirator in a Detector
VESDA-E VEP/VEU/VES: How to Replace the Aspirator in a Detector
VESDA-E VEP/VEU/VES: How to Replace the Sampling Module in a Detector
Play Video: VESDA-E VEP/VEU/VES: How to Replace the Sampling Module in a Detector
VESDA-E VEP/VEU/VES: How to Replace the Sampling Module in a Detector
VESDA-E VEP/VEU/VES: How to Replace the Filter
Play Video: VESDA-E VEP/VEU/VES: How to Replace the Filter
VESDA-E VEP/VEU/VES: How to Replace the Filter
VESDA-E VEP/VEU/VES: How to Replace the Smoke Detection Chamber
Play Video: VESDA-E VEP/VEU/VES: How to Replace the Smoke Detection Chamber
VESDA-E VEP/VEU/VES: How to Replace the Smoke Detection Chamber
VESDA-E VEP: How to Upgrade a VESDA VLP to a VESDA-E VEP
Play Video: VESDA-E VEP: How to Upgrade a VESDA VLP to a VESDA-E VEP
VESDA-E VEP: How to Upgrade a VESDA VLP to a VESDA-E VEP

RELATED PRODUCTS

VESDA-E VEU
VESDA-E VEU Aspirating Smoke Detector (Highest Sensitivity ASD)
VESDA-E VEA
VESDA-E VEA Aspirating Smoke Detector - Minimum Disruption with Centralized Test and Maintenance
VSC
VSC Configuration & Commissioning Software
VSM4
VSM4 Configuration & Monitoring Software
VESDA Pipe - Fittings
VESDA E & VESDA Pipe & Fittings
VESDA Power Supply
VESDA Power Supply
Product information is subject to change without notice. Product images may include options or accessories not included with the base model.

 
OFFER

Schedule a VESDA Lunch & Learn.

A VESDA Lunch and Learn presentation covers the major design aspects of a revolutionary addressable aspirating system (including relevant codes and standards), Advanced Detection products and/or their application in specific markets and case studies. We will provide tea/lunch with a technical exposé on how our very early warning detection products would provide cost savings and the earliest detection for each of your vertical markets.
Xtralis

   Back
Next
Reload